Coordinating fire alarm and elevator recall work means aligning the fire alarm design, elevator controls, building construction schedule, and required reviews and tests. The fire alarm system provides the initiating signals; the elevator controls respond according to the approved sequence of operations.


For building owners and project teams in Anaheim, early coordination can help identify interface requirements before installation and reduce avoidable delays during testing. The exact design and approval path depend on the building, the scope of work, applicable codes, and the authority having jurisdiction (AHJ).



What Are Fire Alarm and Elevator Recall Systems?


A fire alarm system detects and signals fire or other specified conditions. An elevator recall interface uses approved signals to direct elevator operation during certain emergencies.



Phase I elevator recall


Phase I is automatic or manual emergency recall. Depending on the approved design, a qualifying detector or other initiating signal can cause elevators to return to a designated floor. If conditions at that floor require it, the sequence may send the elevators to an alternate floor.



Phase II firefighter operation


Phase II is firefighter operation from inside the elevator cab using the appropriate key controls. It is intended for use by trained emergency personnel under the applicable procedures.


These functions rely on coordinated equipment and programming. The fire alarm contractor and elevator contractor need to agree on the required inputs, outputs, wiring, and sequence before the installation is tested.



Who Is Involved in the Installation?


The property owner or project manager usually coordinates the overall schedule. The technical work involves several parties.



Fire alarm contractor


The fire alarm contractor reviews the existing system or project plans, installs or modifies fire alarm devices and interface equipment, and verifies the fire alarm side of the sequence.



Elevator contractor


The elevator contractor provides requirements for the elevator controller and performs or supports work on the elevator side of the interface. The fire alarm contractor should not assume how the elevator controller is configured.



Design team and general contractor


The engineer or designer documents the intended sequence. The general contractor coordinates access, construction activities, power, pathways, and work between trades.



Fire department or other authority having jurisdiction


The AHJ reviews and inspects work according to local requirements. Anaheim Fire & Rescue’s Life Safety Section provides fire-code permits, inspections, and planning consultations. Confirm the applicable review path and requirements for your project with the City before work begins.



How to Coordinate the Project



1. Review the building and existing systems


Start with the building’s fire alarm plans, elevator documentation, inspection records, and any previous correction notices. Confirm the number of elevators, their served floors, the existing fire alarm control equipment, and whether the work is new construction, modernization, or an alteration.


This review helps the project team identify missing information early. If the existing plans or sequence of operations are incomplete, the design team may need to document them before installation.



2. Confirm the required sequence of operations


The sequence describes what each initiating event should do. It should identify which signals trigger recall, which floor is the primary recall floor, what alternate floor applies, and how any related supervisory or shutdown functions operate when required.


The team should resolve these details with the elevator contractor and design professional before wiring or programming. A written sequence gives installers and inspectors a shared reference for installation and testing.



3. Coordinate drawings, permits, and schedule


The project team should determine which plans, permits, and inspections are required for the specific Anaheim property. Include the fire alarm and elevator interface details in the relevant submittals, and schedule the work so that both trades can access the necessary equipment.

The City’s Life Safety Section can provide information about permits and planning consultations. Its current requirements and the project’s scope should guide the submittal—not assumptions based on another city’s process.



4. Install and program the interface


The fire alarm and elevator contractors install and configure their respective equipment according to the approved design and manufacturer requirements. They coordinate wiring terminations, relay or interface modules, controller inputs, labeling, and any required supervision.


Changes made in the field should be documented and reviewed with the design team and AHJ when required. Unapproved changes can create mismatches between the plans, the installed equipment, and the intended operation.



5. Test the complete sequence with both trades


A successful test checks the end-to-end function: the correct initiating signals occur, the fire alarm system reports the expected conditions, and the elevator responds as shown in the approved sequence. The test should involve the fire alarm and elevator contractors and follow the AHJ’s inspection process.


The team should record results, address deficiencies, and retest affected functions. Do not treat a component check as proof that the full interface works.



Common Coordination Problems to Avoid



Starting installation before the interface is defined


If contractors begin work without an agreed sequence, the elevator controller and fire alarm programming may not match. Resolve the design details first.



Assuming the elevator contractor handles the fire alarm work


The elevator contractor may handle elevator controls, but the scope for fire alarm devices, wiring, programming, documentation, and testing should be clearly assigned in writing.



Testing only one side of the system


Testing the fire alarm panel alone does not confirm that the elevator responds correctly. Testing should verify the complete signal path and sequence.



Overlooking building operations


For occupied properties, coordinate access, resident or tenant notices, elevator downtime, and any temporary safety procedures with the building manager. Keep occupants informed about planned interruptions and restoration.



Why Choose Cyber Shield Security?


Cyber Shield Security works with property owners, managers, general contractors, and developers on fire alarm installation and service needs. The team can review the project scope, discuss the fire alarm interface, and help coordinate with the other trades involved.


The service locations provided for Cyber Shield Security include Los Angeles, North Hollywood, Studio City, Burbank, Sierra Madre, Arcadia, Pasadena, Woodland Hills, Sherman Oaks, Santa Monica, Beverly Hills, and West Hollywood. Anaheim is outside that listed area, so contact the company to confirm service availability for your project before scheduling.



Frequently Asked Questions


Does every building need an elevator recall system?


Requirements depend on the building, elevators, applicable codes, and AHJ direction. Have the project’s design professional and local authority determine what applies.



Does a fire alarm contractor install the elevator controls?


The fire alarm contractor typically handles the fire alarm devices and interface work within its scope. The elevator contractor handles elevator controls and related work. The project team should define responsibilities before construction.



What information should the sequence of operations include?


It should document the initiating conditions and the resulting fire alarm and elevator actions, including designated recall floors and related supervisory or shutdown functions when applicable. The project design and AHJ determine the details.



Can elevator recall be added to an existing fire alarm system?


It may be possible, but the existing panel, wiring, elevator controls, documentation, and applicable requirements must be reviewed first. The AHJ may require plans, permits, or inspections for the alteration.



Who tests the fire alarm and elevator recall interface?


The fire alarm and elevator contractors should coordinate the end-to-end test. The AHJ may also inspect or witness tests based on local requirements and project scope.



How can a building reduce elevator downtime during installation?


Schedule the work with the elevator contractor and property manager, plan building access and tenant notices, and coordinate testing in advance. Actual downtime depends on the equipment and project scope.



Who approves fire alarm and elevator recall work in Anaheim?


The authority having jurisdiction determines the applicable review and inspection requirements. Anaheim Fire & Rescue’s Life Safety Section handles fire-code permits, inspections, and planning consultations; confirm your project’s requirements directly with the City.