Before tenant improvement work begins, the property team should confirm how the project affects the existing fire alarm system, who is responsible for each task, and what approvals or testing may be required. Coordinate the fire alarm vendor with the property manager, tenant, general contractor, other trades, and local authority having jurisdiction (AHJ).


Early coordination helps identify device changes, access needs, potential system impairments, and schedule dependencies before they disrupt construction or building operations.



1. Define the Tenant Improvement Scope


Start with a clear description of the work area and construction plans. Identify changes to walls, ceilings, room layouts, occupancy, or use that could affect fire alarm devices or system coverage.


Ask the fire alarm vendor to review:


  • The affected tenant space and surrounding common areas

  • Existing fire alarm plans and inspection records

  • Devices that may be moved, added, or affected

  • Connections to other building systems

  • The proposed construction schedule and phasing


Do not assume the fire alarm system serves only the tenant’s suite. In many buildings, tenant spaces connect to shared panels or building-wide systems. Have the vendor confirm how the affected space connects to the existing system.



2. Assign Roles and Approvals


Identify one project contact for each party: property management, tenant, general contractor, fire alarm contractor, and any other trades whose work could affect the system. Confirm who can approve scope changes, coordinate access, communicate outages, and arrange inspections.


Before work begins, ask:


  • Who prepares fire alarm drawings or revisions?

  • Who submits plans and permit applications, if required?

  • Who schedules inspections and testing?

  • Who coordinates with the AHJ?

  • Who approves added work and related costs?


The answers can vary by jurisdiction and project scope. In the City of Los Angeles, LADBS identifies fire alarm systems among electrical systems that may require plan check before a permit is issued, with specific exceptions. Confirm requirements for the actual project. LADBS plan check and permit guidance



3. Coordinate Device Protection and Construction Work


Construction can affect detectors, notification appliances, wiring, and other components. Coordinate device protection, ceiling work, dust-producing activities, electrical work, and any temporary coverings or removals with the qualified fire alarm contractor.


Ask the contractor to identify:


  • Devices located in or near the construction area

  • Work that could damage or obstruct devices

  • Whether any temporary removal or relocation is proposed

  • How device locations will be verified after construction

  • What testing is needed after work is complete


Do not let a trade disconnect, cover, relocate, or alter fire alarm equipment without authorization and coordination with the appropriate fire alarm professional.



4. Plan for System Impairments and Occupant Communication


Ask whether the project could affect any portion of the fire alarm system or its monitoring connection. Confirm the expected duration, affected areas, responsible contacts, and steps for communicating system status.


If an impairment is expected or discovered, follow the property’s impairment procedures and the AHJ’s direction. Coordinate tenant notices and any required temporary measures before the work starts. Never assume the system can be taken offline without notifying the responsible parties.



5. Coordinate the Fire Alarm Work With Other Trades


Fire alarm changes often overlap with ceiling, electrical, HVAC, sprinkler, elevator, and access work. Hold a coordination meeting before construction to identify dependencies and avoid rework.

For example, confirm who will provide access to above-ceiling areas, who will notify the fire alarm contractor before ceilings are closed, and which trade will report changes that could affect device placement or wiring.


Keep a current schedule with the fire alarm work, inspections, and any required re-testing clearly marked.



6. Confirm Permits, Inspections, and Testing


Plan review, permits, and inspections depend on the property’s address, the type of building, and the scope of work. Los Angeles County Fire Department recommends using its service locator or contacting Fire Prevention to confirm whether a project is within County jurisdiction. The County also describes plan submission and inspection routes for projects it reviews. Los Angeles County Fire Department construction plan review and jurisdiction guidance


In the City of Los Angeles, LADBS and LAFD publish separate responsibilities for installation inspection and fire alarm testing. The exact process for a tenant improvement should be confirmed with the applicable departments and project team. LADBS fire alarm systems testing guidance

Before approving project closeout, confirm that required testing and inspections are scheduled and that any correction items have been resolved.



7. Collect Closeout Documents and Update Property Records


At the end of the project, request the documents needed to maintain an accurate system history. Depending on the work, these may include revised plans, permits, inspection records, test reports, service documentation, and equipment information.


Update the property’s records with:


  • Changes to device locations or system configuration

  • Work completed and test results

  • Inspection or approval status

  • Remaining deficiencies or recommendations

  • Current vendor and emergency contacts


Keep the records with the building’s existing fire alarm plans and service history so future managers and contractors can understand what changed.



Why Choose Cyber Shield Security?


Tenant improvements involve multiple teams, schedules, and building systems. Cyber Shield Security works with property managers, commercial property owners, apartment building owners, HOAs, general contractors, developers, and business owners on fire alarm service and installation projects.


A site review before construction can help identify existing system considerations, access needs, and coordination questions while the project team is planning the work.



Frequently Asked Questions



Does every tenant improvement require fire alarm work?


No. It depends on the project, existing system, building conditions, and applicable requirements. Have the fire alarm contractor and AHJ review the scope before construction begins.



Can a general contractor disconnect a fire alarm device during construction?


Do not allow devices to be disconnected, covered, relocated, or altered without authorization and coordination with the qualified fire alarm contractor and property team.



Who is responsible for fire alarm plans and permits?


Responsibility should be assigned in writing among the owner, contractor, design team, and fire alarm vendor. The AHJ determines what plans, permits, or approvals are required.



Can tenant improvement work affect the building’s fire alarm system outside the tenant space?


It can, depending on how the system is configured. Ask the fire alarm vendor to confirm which devices, circuits, panels, or shared systems serve the affected area.



What should happen if the fire alarm system needs to be impaired?


Follow the property’s impairment procedures and the AHJ’s direction. Confirm affected areas, notifications, responsible contacts, and the plan for restoring service.



When should fire alarm testing take place?


Coordinate testing with the project schedule and applicable inspection requirements. Confirm with the AHJ and fire alarm contractor which tests and inspections are needed before the space is occupied or the project is closed.



What records should be collected after tenant improvement work?


Keep revised plans, permit and inspection documents, test reports, service records, and a summary of system changes. Update the building’s fire alarm inventory and service history.



Contact Cyber Shield Security


Planning tenant improvements in Los Angeles, North Hollywood, Studio City, Burbank, Sierra Madre, Arcadia, Pasadena, Woodland Hills, Sherman Oaks, Santa Monica, Beverly Hills, or West Hollywood? Contact Cyber Shield Security to discuss fire alarm coordination, repairs, or installation for your project.