Planning an Elevator Recall System Installation in Sacramento

Writer: Isabella R.
Isabella R.
Nov 13
4 min read


An elevator recall system coordinates a building’s fire alarm system with its elevators. When configured fire alarm devices detect smoke in designated areas, the system can signal the elevator controller to move elevators to a designated floor or, under specified conditions, an alternate floor.

Planning an elevator recall installation in Sacramento starts with a review of the existing fire alarm and elevator systems. The fire alarm contractor, elevator contractor, building team, design professionals, and local authority having jurisdiction (AHJ) need to coordinate the design, permits, installation, and testing. Requirements depend on the building, equipment, and adopted codes, so confirm the project scope with the AHJ before work begins. California’s Fire Code addresses fire alarm interfaces and elevator emergency operation; NFPA’s fire alarm overview illustrates how fire alarm signals can initiate elevator recall. California Fire Code, Chapter 9




What an Elevator Recall System Does


Elevator recall is a fire and life safety function. The fire alarm system uses approved inputs and interface equipment to signal the elevator controller. Depending on the design and which device activates, elevators may return to a designated recall floor or an alternate floor.


The exact sequence must match the approved plans and the elevator equipment. It should not be assumed that every alarm signal causes the same elevator response.



Steps to Plan an Elevator Recall Installation



1. Review the Existing Building Systems


Start by reviewing the fire alarm panel, elevator controller, existing detectors and interfaces, system drawings, and prior inspection or service reports. Confirm the number of elevators, served floors, existing recall behavior, and known system deficiencies.


This review helps the project team decide whether the work requires a new installation, an upgrade, or corrections to existing equipment.



2. Coordinate the Design and Responsibilities


Identify who is responsible for each part of the work. The fire alarm contractor handles the fire alarm system and its interface; the elevator contractor addresses the elevator controller and elevator operation. Depending on the project, the design team, electrical contractor, property manager, and AHJ may also need to participate.


The plans should define the system inputs and intended outputs, including designated and alternate recall floors. NFPA’s fire alarm overview describes an input/output matrix as a way to document how alarm inputs relate to system outputs, including elevator recall. NFPA Fire Alarm Basics



3. Confirm Permits and Local Review


Before installation, ask the project team which plans, permits, and reviews are required for the specific Sacramento property. Requirements may vary by building type, project scope, and local jurisdiction. The AHJ should confirm the applicable submittal and inspection process.



4. Schedule Installation With Building Operations


Coordinate access to the fire alarm control panel, elevator lobbies, machine rooms or control spaces, and other areas identified in the approved design. Plan tenant or staff notices, elevator availability, vendor schedules, and any required fire watch or impairment procedures with the responsible parties.


Do not disconnect or bypass life safety equipment without following the building’s approved impairment procedures and direction from qualified personnel.



5. Test the Interface and Document Results


The fire alarm and elevator teams should coordinate testing according to the approved plan and the AHJ’s requirements. The testing plan should verify that the relevant fire alarm inputs and interface devices operate as designed, that the elevator behavior matches the approved sequence, and that any temporarily disabled equipment is restored.


NFPA materials distinguish testing the fire alarm interface from testing the full elevator emergency function; other applicable codes, standards, design documents, or AHJ requirements may call for end-to-end testing with elevator personnel present. NFPA 72 committee report on interface testing

Keep the approved plans, test records, deficiency corrections, and final approval documents with the building’s fire alarm and elevator records.



Common Planning Issues to Address Early


  • Incomplete or outdated fire alarm and elevator drawings

  • Unclear responsibility for wiring, programming, or controller changes

  • Conflicting recall-floor assumptions

  • Limited access to elevator equipment areas

  • Inadequate scheduling between fire alarm and elevator contractors

  • Uncoordinated occupant notifications or elevator downtime

  • Missing records of testing, repairs, or final sign-off


Addressing these items during planning can reduce avoidable delays and make project handoffs clearer.



Why Choose Cyber Shield Security?


Cyber Shield Security works with property owners, managers, contractors, and developers on fire alarm installation and related system projects. A review of the building’s existing fire alarm equipment and project scope can help identify what information and coordination are needed before work begins.


Cyber Shield Security’s stated target communities include Los Angeles, North Hollywood, Studio City, Burbank, Sierra Madre, Arcadia, Pasadena, Woodland Hills, Sherman Oaks, Santa Monica, Beverly Hills, and West Hollywood. Sacramento is outside that stated service-area list, so Sacramento property teams should contact the company to confirm availability.



Frequently Asked Questions



Is elevator recall part of the fire alarm system?


The fire alarm system can provide signals to the elevator controller through an approved interface. The elevator controller carries out the elevator operation according to its design and applicable requirements.


Does every fire alarm signal recall the elevators?


Not necessarily. The response depends on the approved system design, initiating device, elevator configuration, and applicable code requirements.



Which contractors should coordinate the installation?


At minimum, the fire alarm contractor and elevator contractor should coordinate the interface and testing. The design team, electrical contractor, building manager, and AHJ may also have project roles.


Are permits or plan reviews required in Sacramento?


The AHJ determines the applicable requirements for the property and project scope. Confirm required plans, permits, inspections, and approvals before installation begins.



Can the building keep its existing fire alarm panel?


Possibly. A qualified review can determine whether the existing panel, wiring, devices, and programming can support the proposed interface or need upgrades.



Who should be present for system testing?


The fire alarm and elevator contractors should coordinate testing. Elevator mechanics may need to be present for operational testing, depending on the test plan and requirements.



Does Cyber Shield Security serve Sacramento?


Sacramento is not included in Cyber Shield Security’s stated target communities. Contact the company to ask whether it can support your project.



Contact Cyber Shield Security


Planning an elevator recall project or a related fire alarm installation? Contact Cyber Shield Security to discuss the existing system, project requirements, and service availability.

Call (310) 242-3100 or email info@cybershieldsecurity.us. Sacramento property teams should confirm availability; property owners and managers in the company’s listed Los Angeles-area communities can also request a project review.

 
 
bottom of page